Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Braz. dent. j ; 32(2): 53-63, Mar.-Apr. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1339327

ABSTRACT

Abstract The present study was a prospective, controlled, randomized, clinical short-term trial aiming to evaluate the clinical performance of adhesively luted, lithium disilicate and feldspathic glass-ceramics onlays over a period up to 2 years. A total of 11 patients (7 female, 4 male; age range: 18-60 years, mean age: 39 years) were selected for this study. Each patient received a maximum of two restorations per group in a split-mouth-design. LD: Eleven onlays, performed with lithium disilicate-based ceramic (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein), and FP: Eleven onlays, performed with feldspathic ceramic (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Recalls were performed at 2 weeks (baseline = R1), 1 year (R2) and 2 years (R3) after the cementation by three calibrated blinded independent investigators using mirrors, magnifying eyeglasses, probes and bitewing radiographs. The postoperative sensitivity, secondary caries, marginal integrity, marginal discoloration, color match, surface roughness, tooth integrity, and restoration integrity were evaluated. The Friedman test was used to determine if there was a statistically significant difference in time-to-time comparison of the parameters in the ceramics restorations. A total of 95.4% of the restorations were clinically acceptable at the 2-year recall, without a difference for any evaluation parameter for both ceramic materials. Based on the 2-year data, the CAD-CAM onlays manufactured with feldspathic and lithium-disilicate based ceramics showed similar clinical performance.


Resumo O presente estudo é um estudo clínico prospectivo, controlado, randomizado e de longo curto prazo, com o objetivo de avaliar o desempenho clínico de restauraç ões adesivas cerâmica vítrea reforçada com dissilicato de lítio e cerâmica feldspática por um período de até 2 anos. Um total de 11 pacientes (7 mulheres, 4 homens; faixa etária: 18-60 anos, idade média: 39 anos) foram inseridas para este estudo. Cada paciente recebeu duas restaurações por grupo em um delineamento de boca dividida. LD: Onze onlays, realizados com cerâmica à base de dissilicato de lítio (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein); e FP: Onze onlays, realizados com cerâmica feldspática (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Os retornos foram realizados em 2 semanas (linha de base = R1), 1 ano (R2) e 2 anos (R3) após a cimentação, por três investigadores independentes, cegos e calibrados, usando espelhos, óculos de aumento, sondas e radiografias interproximais. Foram avaliadas a sensibilidade pós-operatória, cárie secundária, integridade marginal, descoloração marginal, correspondência de cores, rugosidade da superfície, integridade dentária e integridade da restauração. O teste de Friedman (95%) foi utilizado para determinar se havia uma diferença estatisticamente significante na comparação periódica dos parâmetros nas restaurações cerâmicas. Um total de 95,4% das restaurações estava clinicamente aceitável no retorno de 2 anos, sem diferença para qualquer parâmetro de avaliação para ambos os materiais cerâmicos. Com base nos dados de 2 anos, as restaurações CAD-CAM fabricados com cerâmica feldspática e à base de dissilicato de lítio apresentaram desempenho clínico semelhante.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Young Adult , Inlays , Mouth , Prospective Studies , Dental Porcelain
2.
Braz. dent. sci ; 24(3): 1-7, 2021. tab, graf
Article in English | BBO, LILACS | ID: biblio-1282175

ABSTRACT

Objective: To evaluate the efficacy of different fluoride varnishes on white spot lesions (WSL) remineralization. Material and Methods: Polished bovine enamel specimens were obtained (n = 60) and had their initial surface Knoop microhardness (SMH) determined. WSL were created and the SMH was measured again. Then, specimens were allocated into six groups: C ­ Control (without varnish); BF ­ Bifluorid 12 (6% NaF + 6% CaF2); DP ­ Duraphat (5% NaF); PF ­ Profluorid (5% NaF); FP - Fluor Protector (0.2% NaF + 0.9% difluorsilane); CW - Clinpro White Varnish (5% NaF + 5% TCP). After varnishes application, specimens were immersed in artificial saliva for 24 h. Then, pH-cycling was performed for 8 days and SMH was measured. Data were analyzed by one-way ANOVA and Tukey's test. Results: Non-significant differences were observed among the groups at baseline (p = 0.187) and after WSL formation (p = 0.999). After treatments, significant differences were observed among the groups (p = 0.001). Mean % of alteration (SD) and results of Tukey test were: C- 92.40 (12.10)a; PF- 88.66 (10.66)a; FP- 85.90 (14.49)ab; BF- 67.85 (17.86)bc; CW- 66.60 (18.48)c; DP- 58.62 (8.69)c. Conclusion: Bifluorid 12, Clinpro White Varnish, and Duraphat showed higher efficacy than artificial saliva in promoting the remineralization of WSL, nevertheless, none of the treatments were able to recover sound enamel baseline microhardness (AU)


Objetivo: Avaliar a eficácia de diferentes vernizes fluoretados na remineralização de lesões de mancha branca (LMB). Material e métodos: Espécimes de esmalte bovino polido (n = 60) foram submetidos à análise de microdureza superficial Knoop (KMH) inicial. Foram então criadas LMB artificialmente e os espécimes foram alocados em seis grupos: C ­ Controle (sem aplicação de verniz); BF ­ Bifluorid 12 (6% NaF + 6% CaF2); DP ­ Duraphat (5% NaF); PF ­ Profluorid (5% NaF); FP - Fluor Protector (0.2% NaF + 0.9% difluorsilano); CW - Clinpro White Varnish (5% NaF + 5% TCP). Após a aplicação dos vernizes, os espécimes ficaram imersos em saliva artificial por 24h e uma ciclagem de pH foi realizada por 8 dias. Após a ciclagem, KMH final foi realizada. Os dados foram analisados por ANOVA e teste de Tukey (5%). Resultados: Não foi observada diferença significante para os grupos após a KHM inicial (p = 0.187) e após a formação de LMB (p = 0.999). Após os tratamentos, diferenças significativas foram observadas entre os grupos (p = 0.001). Valores de média de % de alteração superficial (desvio-padrão) e resultados do teste de Tukey foram: C- 92.40 (12.10)a; PF- 88.66 (10.66)a; FP- 85.90 (14.49)ab; BF- 67.85 (17.86)bc; CW- 66.60 (18.48)c; DP- 58.62 (8.69)c. Conclusão: Os vernizes Bifluorid 12, Clinpro White Varnish e Duraphat apresentaram maior eficácia na remineralização das LMB quando comparados à saliva artificial, entretanto, nenhum dos produtos testados foi capaz de recuperar os valores iniciais de microdureza. (AU)


Subject(s)
Animals , Cattle , Fluorides, Topical , Dental Caries , Fluorine
3.
Rev. odontol. UNESP (Online) ; 47(4): 237-243, jul.-ago. 2018. tab, ilus
Article in English | LILACS, BBO | ID: biblio-961522

ABSTRACT

Introduction: Implant inclinations can be corrected using mini abutments at different angulations. Objective: To analyze the influence of external hexagon implants in different inclinations (3 levels) on the microstrain distribution generated around three implants. Method: A geometric bone model was created through Rhinoceros CAD software (version 5.0 SR8, Mcneel North America, Seattle, WA, USA). Three implants (4.1 × 13 mm) were modeled and inserted inside the substrate at three different inclinations: 0º, 17º and 30º. Next, all groups received mini conical abutments, fixation screws and a simplified prosthesis. The final geometry was exported in STEP format to analysis software and all materials were considered homogeneous, isotropic and linearly elastic. An axial load (300N) was applied on the center of the prosthesis. An in vitro study was conducted with same conditions and groups for validating the tridimentional model. Result: Stress was concentrated on the external area of the implants, in contact with the cortical bone and external hexagon. For the bone simulator, the strain increased in the peri-implant region according to the increase in the implant's inclination. The difference between groups was significant (p = 0.000). The 30º group presented higher stress and strain concentration. Conclusion: The microstrain and stress increase around implants directly proportional to the increase of the installation angle.


Introdução: A inclinação dos implantes pode ser corrigida através de mini-pilares de diferentes angulações. Objetivo: Analisar a influência de implantes com hexágono externo em diferentes inclinações (3 níveis) na distribuição de microdeformações geradas em torno de três implantes. Método: Um modelo geométrico de osso foi criado através do software CAD Rhinoceros (versão 5.0 SR8, Mcneel North America, Seattle, WA, EUA). Três implantes (4,1 × 13 mm) foram modelados e inseridos no interior do substrato em três diferentes inclinações: 0º, 17º e 30º. Em seguida, todos os grupos receberam mini-pilares cônicos, parafusos de fixação e prótese simplificada. A geometria final foi exportada em formato STEP para software de análise e todos os materiais foram considerados homogêneos, isotrópicos e linearmente elásticos. Uma carga axial (300N) foi aplicada no centro da prótese. Um estudo in vitro foi conduzido com as mesmas condições e grupos para validar o modelo tridimensional. Resultado: A concentração de tensão ocorreu na área externa dos implantes, em contato com o osso cortical e o hexágono externo. Para o simulador ósseo, a deformação aumentou na região peri-implantar de acordo com o aumento da inclinação do implante. A diferença entre os grupos foi significativa (p = 0.000). O grupo de 30º apresentou maior concentração de tensão e deformação. Conclusão: O aumento da microdeformação e das tensões ao redor dos implantes aumenta diretamente proporcional ao aumento do ângulo de instalação.


Subject(s)
Dental Prosthesis, Implant-Supported , Finite Element Analysis , Dental Implantation
4.
Rev. odontol. UNESP (Online) ; 46(1): 56-60, jan.-fev. 2017. tab, ilus
Article in English | LILACS, BBO | ID: biblio-845607

ABSTRACT

Introduction: The fit between abutment and implant is crucial to determine the longevity of implant-supported prostheses and the maintenance of peri-implant bones. Objective: To evaluate the vertical misfit between different abutments in order to provide information to assist abutment selection. Material and method: UCLA components (N=40) with anti-rotational system were divided as follows: components usinated in titanium (n=10) and plastic components cast proportionally in titanium (n=10), nickel-chromium-titanium-molybdenum (n=10) and nickel-chromium (n=10) alloys. All components were submitted to stereomicroscope analysis and were randomly selected for characterization by SEM. Result: Data were analyzed using mean and standard deviation and subjected to ANOVA-one way, where the groups proved to statistically different (p=<0.05), followed by Tukey’s test. Conclusion: The selection of material influences the value of vertical misfit. The group machined in Ti showed the lowest value while the group cast in Ni Cr showed the highest value of vertical misfit.


Introdução: O ajuste entre a prótese e o implante é fundamental para determinar a longevidade do tratamento e manutenção do osso periimplantar. Objetivo: Avaliar o desajuste vertical entre diferentes infraestruturas metálicas e plataforma dos implantes, a fim de fornecer informação, para auxiliar na escolha do metal a ser utilizado. Material e método: O estudo utilizou componentes do tipo UCLA (N=40), com antirrotacional, foram divididos da seguinte forma: componentes usinados em titânio (n=10), componentes fundidos em titânio (n=10), níquel-cromo-titânio-molibdênio (n=10) e em níquel-cromo (n=10). Após o torque, as amostras foram analisados em estereomicroscópio. Para caracterização em MEV, foram utilizadas as amostras mais representativas, com maior e menor desajuste vertical. Resultado: Os dados foram analisados por média e desvio padrão e submetidos ao teste ANOVA ONE way, onde os grupos foram estatisticamente diferentes (p=<0,05), seguido do teste TUKEY. Conclusão: A escolha do infraestrutura influencia no valor do desajuste vertical, sendo que o grupo usinado em Ti apresentou o menor valor de desajuste, e o grupo fundido em Ni Cr o grupo com maior valor de desajuste vertical.


Subject(s)
Titanium , In Vitro Techniques , Microscopy, Electron, Scanning , Analysis of Variance , Dental Prosthesis , Prosthesis Implantation , Dental Implantation
5.
Braz. dent. sci ; 20(1): 32-39, 2017. ilus, tab, graf
Article in English | LILACS, BBO | ID: biblio-836683

ABSTRACT

Objetivo: Este estudo in vitro avaliou as microdeformações em torno de implantes, sob a influência da angulação e do desajuste vertical em próteses parciais fixas implanto-suportada de três elementos, durante uma carga axial por análise de extensometria. Material e Métodos: Três implantes de hexágono externo com a configuração linear e três implantes de hexágono externo angulado em 17 °, foram inseridos em dois blocos de poliuretano. Para medir a microdeformação, quatro extensômetros foram colados sobre a superfície de cada bloco. Coifas plásticas foram adaptadas a um padrão de resina e fundidas posteriormente. Uma carga axial de 30 kgf foi aplicada sobre o centro de cada implante durante 10 segundos, usando um dispositivo de aplicação de carga. O desajuste vertical foi medido em seis pontos diferentes, utilizando um microscópio estéreo com 100 X amplificação. Resultados: Os resultados mostraram que os valores para diferentes angulações de implantes foram significativos (P = 0,0086). O teste de correlação de Pearson entre deformação e desajuste vertical revelou não haver correlação tanto para o grupo angulado (P = 0,891) quanto para o grupo linear (P = 0,568). Conclusão: As microdeformações foram maiores para os implantes angulados; nenhuma correlação foi encontrada entre o desajuste vertical e os valores de microdeformação (AU)


Objective: This in vitro study was to evaluate micro strains around of implant, under the influence of angulations and vertical misfit in three-element implant-supported fixed partial dentures during axial loading by using strain gauge analysis. Material and Methods: Three external hexagon implants with straight configuration and three external hexagon implants with angled (17°) configuration were inserted into two polyurethane blocks. To measure micro strain, four strain gauges were bonded onto the surface of each block. Plastic copings were adapted to a standard wax pattern and cast. An axial load of 30 kgf was applied on the center of each implant for 10 seconds, using a load application device. The vertical misfit was measured at six different points by using a stereo microscope with 100-X magnification. Results: The results showed that the values for different implant angulations were significant (P = 0.0086). The Pearson's correlation test between micro-strain and vertical misfit revealed no correlation between angled configuration (P = 0.891) and straight configuration (P = 0.568). Conclusion: The micro strain was higher for angled implants; no correlation was found between the vertical misfit and the strain values (AU)


Subject(s)
Dental Implants , Dental Prosthesis
6.
São José dos Campos; s.n; 2017. 77 p. 77, ilus, graf., tab. , graf..
Thesis in Portuguese | LILACS, BBO | ID: biblio-859658

ABSTRACT

O objetivo deste estudo in vitro foi analisar a distribuição das microdeformações geradas ao redor de implantes de hexágono externo, sob a influência da utilização de intermediários do tipo mini pilares cônicos retos e angulados 17° e 30°, sob cargas axiais e não axiais, por meio da análise de elementos finitos e extensometria. Os modelos tridimensionais foram criados simulando três blocos de poliuretano, os quais receberam três implantes cada, um grupo perpendicular e outros dois com fixações inclinadas em 17° e 30°. Para o estudo também foram modelados os intermediários do tipo mini pilar cônico reto e angulados e uma supraestrutura metálica padronizada para ambos os grupos, os materiais foram considerados homogêneos, isotrópicos e lineares. Após a confecção, as geometrias foram exportadas em malhas para o software de análises (ANSYS 15.0, ANSYS Inc., Houston, USA), um carregamento axial de 30 kgf foi aplicado e os valores de tensão e as microdeformações foram analisados. Para análise in vitro, foram confeccionados blocos idênticos aos desenhados anteriormente. Foram colados sete extensômetros na superfície dos blocos, quatro tangenciando cada um dos implantes e três na transversal dos implantes. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Para aplicação de cargas foi utilizado um dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf. durante 10 segundos. Os dados obtidos foram submetidos aos testes ANOVA e Tukey (p< 0,05). Observou-se diferença estatística para os fatores "Angulação do implante" (P=0,000) e o fator "Ponto de aplicação de carga" (P=0,000). Os dados obtidos pela análise de elementos finitos foram apresentados como: resultados qualitativos de tensão que foram analisados seguindo o esquema de cores da escala e resultados de valores de deformação, apresentados em gráficos, onde se observou maior concentração de tensão nos implantes inclinados em 30° localizados nos pontos não axiais 3 e 5 mm, o mesmo ocorreu com os valores de deformação encontrados na superfície ao redor dos implantes. O estudo concluiu que os implantes inclinados apresentaram maiores valores de microdeformações ao redor dos implantes, sendo as aplicações de cargas não axiais nos pontos 3 e 5 mm responsáveis por produzirem aumento na magnitude. Apenas o grupo reto 0° apresentou resultados dentro do limite fisiológico em todas as configurações de aplicação de carga(AU)


The objective of this in vitro study was to analyze microstrains distribuition generated around external hexagon implants, under the influence of intermediary prosthetic componentes as straight, 17° and 30° angled miniconical abutments, under axial and non-axial loads, by finite elements and strain-gauge analysis. The three-dimensional models were created simulating three polyurethane blocks, being installed three implants each, one perpendicular group and another two with inclined fixations at 17° and 30°. For the study were also created straight and angled miniconical abutments and a standardized metallic superstructure for both groups. The materials were considered symmetrical, isotropic and solid. After the preparation, the geometries were exported in mesh to the analysis software (ANSYS 15.0, ANSYS Inc., Houston, USA). An axial load of 30 kgf was applied and the values of main maximum stress and microstrains were analyzed. For in vitro analysis, blocks identical to those created previously were made, seven strain-gauges were placed on the surface of the block, four tangential to each of the implants and three transverse to the implants. Plastic copings were adapted to a wax pattern and then cast. The metallic superstructure was screwed with a torque of 10 N.cm. For load application, a load application device (DAC) with a load of 30 kgf was used, for 10 seconds. Data were submitted to ANOVA and Tukey tests (p <0.05). Statistical difference was observed for "Implant angulation" factors (P = 0.000) and "Load application point" factor (P = 0.000). The data obtained by the finite element analysis were presented as: qualitative results of stress that were analyzed following the color scheme of the scale and results of deformation values, presented in graphs, where it observed a higher concentration of tension in the inclined implants in 30° at the non-axial points 3 and 5 mm, the same occurred with the deformation values found on the surface around the implants. The study can conclude that the inclined implants had higher values of microdeformations around the implants, and the applications of non-axial loads at points 3 and 5 mm are responsible for producing an increase in magnitude. Only the 0° straight group presented results within the physiological limit in all load application configurations(AU)


Subject(s)
Humans , Dental Implantation , Dental Prosthesis
7.
Braz. dent. sci ; 20(4): 25-31, 2017. ilus, tab
Article in English | LILACS, BBO | ID: biblio-877937

ABSTRACT

Objectives: The aim of the present study was to assess the effect of regular and constant longterm alcohol consumption on the percentage of the remaining periodontal bone support (PBS) and periodontal bone loss (PBL) in adult rats. Material and Methods: Fifty-four (54) rats were divided into 3 groups: Control (daily water intake, n=18) daily alcohol intake (20% ethanol, n=18) and social alcohol intake (20% ethanol 2x a week, n=18). The rats were treated with free-choice access to both ethanol consumption frequencies. They were euthanized after 90 days and their left mandibles were radiographed for PBS measuring. The same left mandibles were defleshed and stained. The PBL was morphometrically assessed by measuring the distance between cement-enamel junction and alveolar bone crest. Results: Did not show difference (p > 0.05) in the amount of consumed alcohol between the social and daily intake groups. Rats also evidenced lower PBS percentage and higher PBL (p<0.05) in both alcohol consumption groups in comparison to the control. Conclusion: The long-term constant and regular same amount alcohol consumption may cause alveolar bone loss and reduce the remaining periodontal bone support in adult rats. Thus, the alveolar bone loss was associated with the amount of consumed alcohol, rather than with periodicity in periodontitis-free rats (AU)


Objetivo: O objetivo do presente estudo foi avaliar o efeito do consumo regular e constante de álcool em longo prazo na porcentagem do suporte ósseo periodontal remanescente (SOP) e perda óssea periodontal (PO) em ratos adultos. Material e Métodos: Cinquenta e quatro (54) ratos foram divididos em 3 grupos: Controle (ingestão diária de água, n = 18), consumo diário de álcool (20% etanol, n = 18) e consumo social de álcool (20% etanol 2x por semana, n = 18). Os ratos foram tratados com acesso de livre escolha a ambas as frequências de consumo de etanol. Eles foram sacrificados após 90 dias e suas mandíbulas esquerdas foram radiografadas para medição do SOP. As mesmas mandíbulas esquerdas foram dissecadas e coradas. A PO foi avaliada morfometricamente medindo a distância entre a junção cimento-esmalte e a crista óssea alveolar. Resultados: Não houve diferença (p> 0,05) na quantidade de álcool consumido entre os grupos de ingestão diária e social. Os ratos também evidenciaram menor porcentagem de SOP e maior PO (p<0,05) em ambos os grupos de consumo de álcool em comparação com o controle. Conclusão: A mesma quantidade consumida constante e regular de álcool em longo prazo pode causar perda óssea alveolar e reduzir o suporte ósseo periodontal remanescente em ratos adultos. Assim, a perda óssea alveolar foi associada com a quantidade de álcool consumido, ao invés da periodicidade em ratos sem periodontite. (AU)


Subject(s)
Animals , Rats , Alcoholism , Alveolar Bone Loss , Ethanol , Periodontal Diseases , X-Rays
8.
Braz. dent. sci ; 20(3): 101-109, 2017. ilus, tab
Article in English | LILACS, BBO | ID: biblio-868113

ABSTRACT

Objetivo: Uma biomecânica ideal que minimiza a tensão entre implante e osso pode proporcionar sucesso para implantes osseointegrados. Este estudo avaliou a concentração de deformação no tecido circundante e a tensão nos componentes de dois implantes com diferentes conexões protéticas através de métodos in vitro e in silico. Material e Métodos: Vinte blocos de poliuretano foram divididos em dois grupos (n = 10), seguido da instalação de hexágono interno (IH) (AS Tecnologia - Titanium Fix, São José dos Campos, Brasil) ou de implantes cone morse (LT) (Bicon Dental Implants). Para o método da extensometria (SG), foram colocados quatro sensores ao redor dos implantes. Para a análise por elementos finitos (FEA), o mesmo bloco foi modelado e analisado. Foi aplicada uma carga axial (30 kgf) para ambas as metodologias. Os valores de tensão e deformação foram analisados quanto à correlação com o SG. Resultados: Para SG, LT apresentou uma média de deformação mais agressiva (-932) que IH (-632). Para FEA, a LT mostrou menor tensão (-547) que IH (-1169). Conclusão: Para os dois sistemas implantes, os valores de microdeformação capazes de induzir remodelação óssea indesejada não foram medidos. No entanto, para o implante IH, a presença de um parafuso de retenção tem a desvantagem de concentrar a tensão, enquanto um pilar sólido dissipa a carga axial através do implante, o que sugere um melhor desempenho para o grupo LT. (AU)


Objective: An ideal biomechanics minimizes the stress between implant and bone that can provide success for osseointegrated implants. This study evaluated the strain concentration in surrounding tissue and stress in the components of two implants with different prosthetic connections through an in vitro and in silico methods. Methods: Twenty polyurethane blocks were divided into two groups (n=10) followed by the installation of internal hexagon (IH) (AS Technology ­ Titanium Fix, São José dos Campos, Brazil) or locking taper implants (LT) (Bicon Dental Implants). For strain gauge (SG) method, four sensors were placed around the implants. For finite element analysis (FEA), the same block was modeled and analyzed. An axial load (30 kgf) was applied for both methodologies. The values of stress and strain were analyzed for correlation to SG. Results: For SG, LT presented a mean of strain most aggressive (-932) than IH (-632). For FEA, LT showed less stress (-547) then IH (-1169). Conclusion: For two implant's system, microstrain values capable to induce unwanted bone remodeling were not measured. However, for IH implant, the presence of a retention screw has the disadvantage to concentrate stress while a solid abutment dissipates the axial load through the implant that suggests a better performance for LT group(AU)


Subject(s)
Dental Implantation , Finite Element Analysis
9.
Braz. dent. j ; 27(5): 543-547, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-828035

ABSTRACT

Abstract The aim of this study was to assess whether surface treatment improves zirconia-porcelain adhesion. The 3Y-TZP blocks were cut into squares, then polished and sintered. The zirconia surface treatments were performed as follows: no treatment (C); tribochemical silica coating (TBS); glaze application + hydrofluoric acid etching (GA); glaze application + hydrofluoric acid etching + silanization (GAS); deposition of silica nanofilm (NF). After treatments, veneering porcelain cylinders (3.3 x 3.3 mm) were built up on all specimens and fired. Then the specimens were subjected to thermal cycling (6000 cycles), and subjected to shear test. Fractures were analyzed by stereomicroscopy and SEM. Data were statistically analyzed by 1-way ANOVA and Tukey's test (5%). Zirconia-porcelain bond strength was affected by the ceramic surface treatments (p=0.0001). GA (19.5±3 MPa) and GAS (16.2±4 MPa) recorded the highest bond strength values, while control group had the lowest bond value (10.1±4 MPa). Adhesive failure of the samples predominated. Therefore, glaze application as 3Y-TZP treatment before veneering porcelain stratification may enhance zirconia-porcelain adhesion.


Resumo O objetivo do estudo foi avaliar o efeito de tratamentos de superfície para melhora a união entre zircônia-porcelana. Os materiais testados foram 3Y-TZP e VM9. Os blocos de 3Y-TZP foram cortados em quadrados, polidos e sinterizados. Os tratamentos de superfície foram: Rocatec soft e aplicação de silano (TBS), vitrificação e ácido fluorídrico (GA), vitrificação, ácido fluorídrico e aplicação de silano (GAS), deposição de nanofilme de sílica (NF) e ausência de tratamento (C). Após os tratamentos, cilindros de porcelana foram construídos sobre as amostras e sinterizados. Após a sinterização da porcelana, todas as amostras foram submetidas a ciclos térmicos (6000 ciclos). Em seguida, os espécimes foram acoplados em uma máquina de ensaio universal e foi realizado o teste de micro cisalhamento a uma velocidade de 1,0 mm/min. As fraturas foram analisadas por estereomicroscópio e MEV. Os dados foram submetidos à ANOVA 1fator e teste de Tukey (5%). A resistência de união zircônia-porcelana foi afetado pelos tratamentos de superfície de cerâmica (p=0,0001). GA e GAS registraram os maiores valores de resistência de união, os valores mais baixos de resistência de união foram observados no grupo C (ausência de tratamento) (19,5 ± 3a, 16,2 ± 4ab e 10,1 ± 4c respectivamente). Houve predominância de falhas adesivas. Portanto, a vitrificação pode ser considerada uma opção para aumentar a resistência de união entre zircônia-porcelana.


Subject(s)
Dental Porcelain/chemistry , Zirconium/chemistry , Microscopy, Electrochemical, Scanning , Surface Properties
10.
Braz. dent. sci ; 18(4): 43-50, 2015. ilus, tab, graf
Article in English | LILACS | ID: lil-786313

ABSTRACT

This study evaluated the hypothesis that different treatments of surface upon three metalalloys for metal ceramic dental prostheses (Gold; Nickel-Chromium; Titanium) do not Influence the values of bond strength with resin cement. Material and Methods: Twenty blocks, 5 x 5 x 5 mm, ofeach alloy were divided into two subgroups (n =10) according to surface treatments: 1 (Primer): sandblasting with aluminum oxide particles 110µm (Al2O3) + Alloy Primer (Kuraray); 2 (Cojet): sandblasting with silica oxide particles with Cojet-Sand + Silane ESPE-Sil. The conditioned blocks ofeach group were cemented, with Panavia F, to resinblocks under constant load of 750 g/10 min. Thesets were cut to obtain 4 samples with dimensions of 10x1x1 mm per block (n = 10) and the adhesive surface with approximately 1 mm2. The microtensile test was done in the universal testing machine at 1 mm/min crosshead speed. The values of bond strength and standard deviation (MPa) were: Au P:7.33 ± 1.93d; Au C: 13.35 ± 2.18c; NiCr P: 23.56± 6.5b; NiCr C: 42.6 ± 5.84a; Ti P: 26.17 ± 1.94b;Ti C: 44.30 ± 2.3a. Data were analyzed by varian cetest (ANOVA) and Tukey’s test, p < 0.05. Results: The results indicated that the conditioning withtreatment 2 increased the bond strength between theresin cement and alloys. The lowest bond strengths values were obtained with gold alloy, regardless the surface treatment. Conclusion: The results denied the hypothesis that the metallic alloys surface treatments do not alter the bond strengths values...


O estudo avaliou a influência de diferentes tratamentos de superfície em três ligas metálicas para próteses dentárias de metalocerâmicas (ouro;níquel-cromo; titanium), nos valores de resistência de união com cimento resinosos. Material e Métodos:Vinte blocos, 5 x 5 x 5 mm, de cada liga foram divididos em dois subgrupos (n = 10) de acordo com os tratamentos de superfície: 1: jateamento com partículas de óxido de alumínio (Al2O3) 110μm + Alloy Primer (Kuraray); 2 (Cojet): jateamento com partículas de óxido de sílica com Cojet-Sand +Silano ESPE-Sil. Os blocos foram cimentados, com Panavia F, a blocos de resina sob carga constante de 750 g / 10 min. Os conjuntos foram cortados para obter assim, 4 amostras com dimensões de 10 x 1x 1 mm por bloco (n = 10) e a superfície adesiva com cerca de 1 mm2. Foi realizado o teste de microtração na máquina de ensaio universal a 1 mm/ min. Os valores de resistência de união e desvios-padrão (MPa) foram: Au P: 7,33 ± 1.93d; Au C:13,35 ± 2.18c; NiCr P: 23,56 ± 6.5b; NICR C: 42,6± 5.84a; Ti P: 26,17 ± 1.94b; Ti C: 44,30 ± 2.3a, e analisados estatisticamente pelo teste de variância(ANOVA) e teste de Tukey, p < 0,05. Resultados: Os resultados indicaram que a resistência de união do condicionamento com o tratamento Cojet aumentou a resistência de união entre o cimento resinoso e ligas. Conclusão: Os valores mais baixos foram obtidos com liga de ouro, independente do tratamento de superfície...


Subject(s)
Humans , Dental Cements , Dental Materials , Resin Cements
11.
Rev. odontol. UNESP (Online) ; 43(5): 351-357, Sep-Oct/2014. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-721494

ABSTRACT

Introdução: O controle das microdeformações ao redor dos implantes é um fator que pode levar a uma melhor osseointegração e manutenção das estruturas ósseas. Objetivo: Avaliar a distribuição de tensões ao redor dos implantes, utilizando-se a extensometria, sob a influência da aplicação de cargas estáticas axiais e não axiais em próteses parciais fixas de três elementos, em diferentes pontos de aplicação de carga. Material e Método: Em um bloco de poliuretano, foram instalados três implantes de hexágono interno e, sobre esses implantes, pilares protéticos microunit foram conectados com torque de 20 Ncm. Cilindros plásticos foram utilizados para realização dos enceramentos padronizados que, posteriormente, foram fundidos em liga de cobalto cromo. Extensômetros foram colados na superfície do bloco ao redor dos três implantes. As estruturas metálicas foram parafusadas com torque de 10 Ncm cada. Em seguida, foram realizados carregamentos verticais estáticos de 30 kgf, durante dez segundos, em cinco pontos pré-determinados (A, B, C, D e E), utilizando um dispositivo de aplicação de cargas (DAC). Resultado: Os dados foram analisados pelo teste RM ANOVA, que indicou que o efeito entre o ponto de aplicação de carga e os diferentes corpos de prova não foi estatisticamente significante, enquanto que, para o efeito entre os pontos de aplicação de carga, houve diferença (p=0,0001). Em seguida, aplicou-se o teste de comparação múltipla de Tukey. Conclusão: A aplicação de carga sobre os pontos não axiais D e E produziu um aumento da magnitude de microdeformação ao redor dos implantes. .


Introduction: The control of the micro strain surrounding implants is a factor that can lead to a better osseointegration and maintenance of bone structures. Objective: evaluate in vitro, using strain gauge analysis , the influence of the axial and non-axial static load in implant-supported fixed partial dentures, varying the point of load application. Material and Method: In a block of polyurethane three internal hexagonal implants were installed, on implants abutments microunit were connected with torque of 20 Ncm, and plastic prosthetic cylinders were screwed on to the abutments, which received standard patterns cast in Co-Cr alloy (n=10). Four strain gauges were bonded on the surface of the block tangentially to the three implants. Each metallic structure was screwed onto the microunit with a 10 Ncm torque. With a load application device (DAC) static vertical loads of 30kgf were applied for ten seconds at five predetermined points (A, B, C, D and E). Result: Result analyzed by RM ANOVA, in which the effect of the point of load application and differents specimens were not statistically significant, whereas regarding the points of load application presented statistical differenced (p=0.0001). Applying Tukey's multiple comparison tests. Conclusion: The application of load on the non-axial points D and E produced an increase in the magnitude of micro strain around implants. .


Subject(s)
In Vitro Techniques , Dental Implants , Analysis of Variance , Dental Prosthesis , Denture, Partial, Fixed , Dental Implantation, Endosseous
12.
Article in Portuguese | LILACS | ID: lil-725986

ABSTRACT

Objetivo: Correlacionar medidas lineares entre radiografias panorâmicas digitais (DPan) e tomografias computadorizadas cone beam (TCcb) na região do seio maxilar. Método: Foram selecionados exames aos pares de 71 sítios, 37 do lado direito e 34 do lado esquerdo, das radiografias panorâmicas digitais e suas correspondentes tomografias computadorizadas cone beam. As radiografias panorâmicas foram obtidas por meio do aparelhoOrthopantomograph® e foram analisadas por meio do software Image Tool v.3.0. As tomografias computadorizadas cone beam foram obtidas pelo tomógrafo i-CAT e analisadas pelo software Dental Slice. As mensurações foram realizadas por medidas lineares da distância da cortical inferior do seio maxilar até a cúspide incisal mais pronunciada do molar. Resultados: A comparação entre medidas apresentou concordância moderada e os valores foram estatisticamente (p<0,05) maiores nas medições da radiografia panorâmica digital compensada, com ampliação de 1,75 a 2,15 mm (8 a 9%), do que as medidas na tomografia computadorizada cone beam. Conclusão: Conclui-se que há necessidade de adicionar margem de segurança de 2,5 mm (10,5%) na região do seio maxilar, após a compensação da magnificação da imagem, quando for utilizada a radiografia panorâmica para planejamento cirúrgico para implantes dentários...


Objective: To correlate linear measurements between digital panoramic radiographs (DPan) and cone beam computed tomography images (CBCT) of the maxillary sinus area. Method: Seventy-one paired site exams were selected, 37 from the right side and 34 from the left side, on digital panoramic radiographs and their corresponding CBCT images. The panoramic radiographs were obtained by the Orthopantomograph®evice and analyzed by the Image Tool v.3.0 software. The CBCT images were obtained by the i-CAT tomograph and analyzed by the Dental Slice software. Linear measurements of the distance between the lower cortical of the maxillary sinus to the sharpest molar cusp. Results: Comparison of the measurements revealed a moderate agreement and the values were significantly higher in the measurements on the compensated digital panoramic radiographs (p<0.05) with 1.75 to 2.15 mm (8 to 9%) magnification, compared with the CBCT images.Conclusion: It may be concluded that when panoramic radiographs are used in the surgical planning for dental implants, a safety margin of 2.5 mm (10.5%) should be added in the maxillary sinus area after compensating for image magnification...


Subject(s)
Humans , Male , Female , Adolescent , Middle Aged , Young Adult , Radiography, Panoramic/instrumentation , Maxillary Sinus , Cone-Beam Computed Tomography/instrumentation , Data Interpretation, Statistical , Software
SELECTION OF CITATIONS
SEARCH DETAIL